| Home | E-Submission | Sitemap | Contact Us |  
top_img
J Korean Soc Emerg Med > Volume 17(3); 2006 > Article
Journal of The Korean Society of Emergency Medicine 2006;17(3): 238-244.
Increased Intracranial Pressure Detected by Emergency Ultrasonography of the Optic Nerve Sheath Diameter
Dae Young Hong, Kang Ho Kim, Kyung Mi Lee, Ji Hye Kim, Jun Sig Kim, Seung Baik Han, Hun Jae Lee, Soon Gu Cho, Young Gil Ko
1Department of Emergency Medicine, College of Medicine, Inha University, Incheon, Korea. LIFSAV@inha.ac.kr
2Department of Social and Preventive Medicine, College of Medicine, Inha University, Incheon, Korea.
3Department of Radiology, College of Medicine, Inha University, Incheon, Korea.
4Department of Emergency Medicine, Inje University Seoul Paik Hospital, Seoul, Korea.
ABSTRACT
PURPOSE:
A rapid, portable, and noninvasive means of detecting increased intracranial pressure (IICP) is desirable when conventional imaging methods are unavailable. The purpose of this study was to show that ultrasonographic measurement of the optic nerve sheath diameter (ONSD) can accurately predict the presence of IICP.
METHODS:
We performed a prospective study of emergency department patients suspected of having IICP due to possible focal intracranial pathology. The ONSD was measured 3 mm behind the globe using a linear probe on the closed eyelids of supine patients. For each patient, the mean of the two ONSD measurements was calculated, and the brain computed tomography (CT) was evaluated for signs of IICP.
RESULTS:
One hundred patients were enrolled; 31 had CT results consistent with IICP, and their mean ONSD was 6.30 mm; the mean ONSD of patients who didn't show signs of IICP on CT was 4.50 mm. The sensitivity and the specificity for the ONSD, when compared with CT results, were 100% and 98.6%, respectively.
CONCLUSIONS:
The evaluation of the ONSD is a simple noninvasive procedure, and is a potentially useful tool in assessing and monitoring patients suspected of having IICP.
Key words: intracranial pressure, Ultrasonography, Optic nerve
TOOLS
PDF Links  PDF Links
Full text via DOI  Full text via DOI
Download Citation  Download Citation
Share:      
METRICS
1,333
View
19
Download
Related article
Editorial Office
The Korean Society of Emergency Medicine
TEL: +82-62-226-1780   FAX: +82-62-224-3501   E-mail: 0012194@csuh.co.kr
About |  Browse Articles |  Current Issue |  For Authors and Reviewers
Copyright © The Korean Society of Emergency Medicine.                 Developed in M2PI