| Home | E-Submission | Sitemap | Contact Us |  
top_img
J Korean Soc Emerg Med > Volume 21(2); 2010 > Article
Journal of The Korean Society of Emergency Medicine 2010;21(2): 227-233.
Using Ultrasound to Diagnosis a Radio-lucent Soft Tissue Foreign Body - in Emergency Departments: A Preliminary Study Using a Swine Model -
Young Kwan Kim, Byung Hak Soh, Chun Song Youn, Jung Hee Wee, Hyung Min Kim, Kyu Nam Park, Hyeon Woo Yim
1Department of Emergency Medicine, College of Medicine, The Catholic University of Korea, Seoul, Korea. dockdo2008@catholic.ac.kr
2Department of Preventive Medicine, College of Medicine, The Catholic University of Korea, Seoul, Korea.
ABSTRACT
PURPOSE:
The purpose of this study is to estimate the accuracy of diagnosing a radio-lucent soft tissue foreign body with using ultrasound according to the different sizes and depth of the foreign bodies in an experimented model.
METHODS:
In the forefeet of swine, we made 45 incisions (4 in each forefeet) of 2 mm, 5 mm and 10 mm sized toothpicks at depths of 1 cm, 2 cm and 3 cm each. 15 incisions without foreign bodies were cannulated, simulating damage to the soft tissue made by a non captured foreign body. The twelve emergency physicians kept records not only for the presence or absence of a foreign body, but also for the depth of it. We then calculated the sensitivity, specificity, PPV (positive predictive value) and NPV (negative predictive value) according to the sizes of the toothpicks and the depths.
RESULTS:
The sensitivity, specificity, PPV and NPV of all the depths and sizes were under 80%. The results of the staff and residents were not significantly different. The result of a 3 cm depth was especially poor.
CONCLUSION:
In our model, ultrasound performed by emergency physicians was neither sensitive nor specific for diagnosing a soft tissue foreign body of various sizes and depths.
Key words: Ultrasonography, Foreign bodies, Emergency
TOOLS
PDF Links  PDF Links
Full text via DOI  Full text via DOI
Download Citation  Download Citation
Share:      
METRICS
1,343
View
8
Download
Related article
The Efficacy of Ultrasound Diagnosis of a Partial Tendon Injury by Emergency Doctors: Using a Swine Model  2010 February;21(1)
Editorial Office
The Korean Society of Emergency Medicine
TEL: +82-62-226-1780   FAX: +82-62-224-3501   E-mail: 0012194@csuh.co.kr
About |  Browse Articles |  Current Issue |  For Authors and Reviewers
Copyright © The Korean Society of Emergency Medicine.                 Developed in M2PI